EDR4 1171 05/05
3
To avoid difficulty during installation, do not connect the opener to the mains or run the door
opener until instructed to do so.
Do not use force sensitivity adjustments to compensate for a binding or sticking garage door.
Excessive force may damage the garage door.
Before installing the drive remove all unnecessary ropes or chains and disable any equipment,
such as locks, that is not needed for powered operation.
Before installing the drive check that the door is in good mechanical condition and that it is
correctly balanced. Check that it opens and closes properly.
Install the actuating member for the manual release (red handle on a rope) such that it rests at a
height of less than 1.8m.
Install any fixed control, wired or wireless, within sight of the door but away from moving parts and
at a height of more than 1.5m.
Permanently attach the label warning against entrapment in a prominent place, or near any fixed
control.
Permanently fix the label concerning the manual release adjacent to its actuating member (thread
the cord through the holes in the manual release warning card).
After installation, ensure that the mechanism is properly adjusted and that the drive reverses when
the door contacts a 50mm high object placed on the floor.
The appliance is not intended for use by young children or infirm persons without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
CE compliance after installation (EC countries only)
It is the responsibility of the installer of the opener to ensure that the forces measured at the
leading edge of the door are within the guidelines of BSEN 60335-2-95:2001. This may require
adjustment of the drive and may also require adjustment of the door. Specialised measurement
equipment may be required. Contact Merlin for assistance if necessary. If the measured forces
exceed the guidelines then Merlin M102 non-contact sensors must be fitted.
Site requirements
Electrical Power Supply The opener is for 220-240 Volts AC - 50 Hz. There
must be an earthed power point within 1.6 metres of the mounting position.
Garage Door This opener is designed for a residential roller door, maximum
3m high, 6m wide and 200kg in gross mass. If the garage door is more than 1.9
m high, 2.1 m wide or 70kg in gross mass, it is recommended that safety beams
are fitted or the leading edge force of the garage door tested. Contact your
merlin dealer for further information.
The force required to move the garage door should not exceed 30kg. Check
that it is possible to raise the door by hand through the full height of the open-
ing. The door should operate smoothly, rolling up and down level to the floor
without the door curtain binding, bulging or coning. The door must not jam in
the tracks. If in doubt consult Merlin.